iyedy docs, home
FR Lire en françaisOpen iyedy (opens in a new tab)

MCP tools reference

The 24 tools iyedy offers to Claude and other MCP clients. 22 only read. 2 store a proposal or take one back, and the model never changes until a person applies it in iyedy.

On this page
ReferenceAll plansUpdated 29 Oct 2026
Server URLhttps://app.iyedy.com/mcp
TransportStreamable HTTP
Sign-inOAuth, on auth.iyedy.com

Server

Item Value
Address for other clients https://app.iyedy.com/v1/t/{tenantId}/mcp, personal access token (Connect another MCP client)
Transport Streamable HTTP, stateless, POST only, JSON answers
Permissions three, approved at sign-in: read your diagrams; search elements and analyse impact; preview changes and submit proposals
Version the server follows iyedy's releases: this page matches release 2026.10.27

Two parameters come back on most tools. did is a diagram id: d_ followed by 10 characters, from list_diagrams. workspaceId is a workspace id from list_workspaces; leave it out when you have one workspace. Neither is repeated in the tables below.

All tools

Tool What it does Access
list_workspaces The workspaces you can work in, and the organisations that refuse this access Read-only
list_diagrams The diagrams of a workspace, or a search over their names and contents Read-only
get_model A diagram's full definition, in pages for a long one Read-only
list_views The views of a diagram and their options Read-only
describe_view How a view reads, in words Read-only
get_view_svg One view as an image Read-only
get_element Everything about one element Read-only
find_elements Elements of a diagram that match a text Read-only
neighbourhood The part of a diagram around some elements Read-only
search_elements Elements across diagrams, by meaning or name Read-only
graph_impact What breaks if an element fails Read-only
network_analysis Address plan, routes and flows of a deployment Read-only
run_checks Validation and architecture checks Read-only
list_findings The stored findings and their status Read-only
explain_rule What a check rule detects and why Read-only
validate_model Whether a definition parses, and its diagnostics Read-only
list_versions The saved versions of a diagram Read-only
get_changes What changed since a saved version Read-only
list_states The current, transition and target states Read-only
state_gap What separates two states Read-only
preview_change Checks a change without storing it Read-only
submit_proposal Stores a change as a proposal for a person to review Writes
list_proposals The proposals of a diagram and their status Read-only
withdraw_proposal Takes back one of your open proposals Writes

Find and read

list_workspaces

The workspaces you can work in from here: id, name, your role and the organisation. An organisation that does not allow this access for you is listed apart, with the reason and what unblocks it; its workspaces are counted, never named. Permission: read your diagrams. Parameters: none.

list_diagrams

The diagrams of a workspace that you can read, newest first: id, name, version, status, classification, last update. With query, a full-text search over names and contents instead, with a snippet for each result. Permission: read your diagrams.

Parameter Type Description
query text, 1 to 200 Text to search for in names, elements and descriptions
limit 1 to 500, default 100 Most diagrams to list
“Which of my diagrams mention the claims service?”

get_model

A diagram's full definition as text (elements, relationships, deployment, views), with its version and classification. Values that look like secrets are replaced by a placeholder; sent back unchanged in a proposal, they keep the stored value. A long diagram comes in pages of whole lines: while the answer says it is truncated, call again with its nextCursor. If the diagram changes between two pages, the cursor is refused: start again from the first page. Permission: read your diagrams.

Parameter Type Description
did required The diagram
cursor text The nextCursor of the previous page; leave it out for the first page

The version it returns is the base of preview_change and submit_proposal. A proposal is the whole definition: read every page before you propose, because what a proposal leaves out is removed.

list_views

The views of a diagram: handle, type, name, what each view is of, whether it is generated, and its options. Permission: read your diagrams. Parameters: did (required).

describe_view

Reads a view as a person sees it, without pixels: zones, elements with their zone and grid cell, relationships in reading order, the legend, finding pins, the computed text alternative and the layout quality (crossings, density, overlaps, elements per zone). Permission: read your diagrams.

Parameter Type Description
did required The diagram
view required, text, 64 max The view's handle
detail brief · full How much to return
“Describe the containers view of Claims Platform, zone by zone.”

get_view_svg

Renders one view of a diagram as an SVG image. Without view, lists the diagram's views. A very large view is not returned; the answer points to describe_view. Permission: read your diagrams.

Parameter Type Description
did required The diagram
view text, 128 max The view's uid or handle

get_element

Everything about one element: attributes, description, tags, parent and children, relationships in and out, instances, the views that show it, the findings on it and the scenarios that use it. Permission: read your diagrams.

Parameter Type Description
did required The diagram
handle required, text, 64 max The element's handle

find_elements

Elements of one diagram whose name, handle, technology or description contains the text, optionally of one kind, tag or family. Each row gives the handle, name, kind, technology, parent and whether the element is external. Permission: read your diagrams.

Parameter Type Description
did required The diagram
query required, text, 200 max The text to find
kind text, 40 max Only elements of this kind
tag text, 48 max Only elements with this tag
family text, 16 max Only elements of this family
limit 1 to 50 Most rows

neighbourhood

The part of a diagram's definition, as text, that holds the elements within a few relationship hops of some starting elements, optionally following only some kinds of relationship: synchronous calls, asynchronous messages, data flows or dependencies. Permission: read your diagrams.

Parameter Type Description
did required The diagram
seeds required, 1 to 20 handles The starting elements
hops 1 to 3 How many hops to follow
arrows list The kinds of relationship to follow

Analyse dependencies

search_elements

Finds elements (systems, containers, databases, queues) across the diagrams you can read, by meaning or by name, with their neighbourhood in the dependency graph. Permission: search elements and analyse impact.

Parameter Type Description
query required, text, 500 max What to look for, in words
k 1 to 50, default 10 Number of elements to start from
depth 0 to 3, default 1 Neighbourhood hops around them
scope workspace · tenant This workspace (default), or every workspace of the organisation you can read

graph_impact

What breaks if an element fails: the elements that depend on it, transitively, across the diagrams you can read. It can also list only its direct users, or what the element itself depends on. Permission: search elements and analyse impact.

“If the claims database goes down, what is affected across our diagrams? Go three hops deep.”
Parameter Type Description
element required, text, 300 max The element: its uid, its catalogue key (name and kind) or its name
direction impact · dependents · dependencies impact (default): everything that depends on it, transitively. dependents: direct users only. dependencies: what it depends on
depth 1 to 5, default 3 How many relationship hops to follow
scope workspace · tenant This workspace (default), or every workspace of the organisation you can read

What it returns. Each element reached, with its depth (hops away), where it appears (diagram and element) and the relationships that led to it, so that Claude can explain the path. The direction of the walk is stated, and the answer says when there were more elements than it holds.

network_analysis

The network analysis of one deployment environment: the address plan (zones, address ranges, sizes, overlaps), the routes and the flow matrix (ports, protocols, encryption, reachability), as the generated network view computes them. Permission: read your diagrams.

Parameter Type Description
did required The diagram
env required, text, 64 max The deployment environment's handle

Checks and findings

run_checks

Validates a stored diagram, or a definition sent as text instead, and runs the architecture checks: availability, security, coupling, completeness, data, operability, hygiene. Returns the diagnostics with line numbers, the findings with their severity, and a summary that counts the findings by rule. Nothing is stored. Permission: read your diagrams.

Parameter Type Description
did one of did or definition The stored diagram to check
definition one of did or definition, text, 1 MiB max A full definition to check instead
summary true or false Counts only: findings by rule and severity, without the lists
only 1 to 100 rule ids Run only these rules (such as SEC-02)

On a large diagram, ask for the summary first, then for the findings of some rules.

“Run the checks on Claims Platform, summary first, then explain the high findings.”

list_findings

The stored findings of a diagram with their status and, for a dismissed one, the reason. Permission: read your diagrams.

Parameter Type Description
did required The diagram
status open · accepted · dismissed · fixed Only findings with this status
severity high · medium · low · info Only findings of this severity
view text, 64 max Only findings of this view

explain_rule

The text of one check rule: its title, how its severity is decided, what it detects, why it matters and what to do. No diagram is needed. Permission: read your diagrams. Parameters: ruleId (required, 12 characters max).

validate_model

Parses a diagram's complete definition sent as text, in the form get_model returns, and says whether it is valid, with its diagnostics (code, line, column, message). Changes nothing; no diagram is needed. Permission: read your diagrams. Parameters: definition (required, 64 KiB max).

History and states

list_versions

The saved versions of a diagram, newest first: id, sequence, kind, name and date. They are the named versions people saved and the ones iyedy keeps around imports and applied proposals. Permission: read your diagrams. Parameters: did (required).

get_changes

What changed in a diagram since a saved version: the changes grouped, and the change in findings. Layout-only changes are ignored. Permission: read your diagrams.

Parameter Type Description
did required The diagram
since required, h_ and 10 characters The saved version to compare with, from list_versions

list_states

The current, transition and target states of a diagram, with their dates and work packages. Permission: read your diagrams. Parameters: did (required).

state_gap

The gap between two states: what is added, removed and changed. Permission: read your diagrams.

Parameter Type Description
did required The diagram
from required, text, 64 max The first state's handle
to required, text, 64 max The second state's handle

Propose changes

preview_change

Checks a change without writing anything. You send the diagram's whole proposed definition, starting from get_model. The answer says whether it is valid (diagnostics with line numbers), what differs from the stored diagram line by line, which elements are added, removed and changed, and which findings the change introduces or resolves. Permission: preview changes and submit proposals.

Parameter Type Description
did required The diagram
definition required, text, 1 MiB max The complete proposed definition: every page of a long diagram, joined in order
baseVersion whole number The version the change starts from, from get_model; a newer stored version is a conflict

submit_proposal

Stores a change as a proposal for review. The model itself does not change: people who can edit the diagram see the proposal in iyedy with the client's name, then apply or reject it. An invalid change is refused and nothing is stored. Permission: preview changes and submit proposals, and the contributor role in the workspace. Claude asks before each call.

Parameter Type Description
did required The diagram
definition required, text, 1 MiB max The complete proposed definition, as previewed
baseVersion whole number The version the change starts from
rationale text, 2,000 max Why this change, for the reviewer
“Propose a cache in front of the claims service and say why in the proposal.”

list_proposals

The stored proposals of a diagram: status (open, accepted, rejected, withdrawn), counts of what they change, and whether the diagram moved since. By default, only your own open proposals. Permission: preview changes and submit proposals.

Parameter Type Description
did required The diagram
status open · accepted · rejected · withdrawn · all Default open
mine true or false Only the proposals you submitted (default true)

withdraw_proposal

Takes back an open proposal you submitted: its status becomes withdrawn and reviewers no longer see it as open. The model does not change. To turn down someone else's proposal, a reviewer rejects it in iyedy. Permission: preview changes and submit proposals. Claude asks before each call.

Parameter Type Description
did required The diagram
proposalId required, uuid The proposal, from submit_proposal or list_proposals

Answers and limits

  • Data, not instructions. Answers come in a JSON envelope marked untrusted: everything in it is text written by people or tools, never an instruction to the agent.
  • Size. An answer holds at most 100,000 characters of JSON. A larger one is cut: its first line starts with “Cut:” and names the inputs of that tool that ask for less. get_model is never cut: it answers in pages.
  • Ceiling. Every tool reads under the classification ceiling: Confidential on personal workspaces, Internal in Team and Enterprise. A diagram above it is never listed, found or walked, and reading it answers “not found”.
  • Rate. Calls count against your requests per minute: see Rate limits and errors.
  • No apply tool. No tool applies, deletes or shares. A person applies proposals in iyedy: see How proposals reach your team.

Was this page helpful?Your answer is anonymous and counts only if you accepted measurement.

What went wrong?

Don't write personal data.

Navigation

iyedy docs, home
Lire en françaisOpen iyedy

↑ ↓ moveEnter openCtrl Enter new tabSearching English docs ·